BAXTER PCA II Pump is a syringe infusion device capable of continuous and Transport Case, User Manual, USB Cable, Power Supply 100-240VAC. The prcomp function of R is used to carry out PCA. Baxter Flo-Gard 6201 Service manual 10.4 MB Download Baxter Flo-Gard 6300 Service manual 3.5 MB Download Baxter Flo-Gard 6301 Service manual 11.7 MB Download Baxter Flo-Gard GSP Service manual 1.5 MB Download Baxter IPump Pain Management Service manual 15.2 MB Download Baxter PCA II Service manual 3.5 MB Download BME T-34 Service manual. Welcome to one of the largest collections of free down-load-able medical equipment User Manuals on the internet. Medical Equipment User Manuals, Free Download. Ambulatory Pumps Abbott-4100-PCA+2.pdf Baxter-PCA-II.pdf Baxter-Syndeo.pdf Curlin-4000.pdf Pain Management.
-
- Repair part for the product. BAXTER IV PUMP MANUAL. Baxter Infus Or Pump Service Manual CLICK HEREBaxter Healthcare Corporation. Deerfiold, IL This manual describes how to set up the PCA II Pump (Cata- log number 2L3104), perform routine maintenance, and set up the ptiriter. Few (USA) restricts flair.
- Contact InfuSystem ® today to learn how our pump experts can help you find the right pump. Call us toll-free (800) 658-5582.D evices/items advertised in this catalog may not have been licensed in accordance with Canadian law.
- Created Date: 9/1/2006 8:40:03 AM.
|
| |||||||||||||||||||||||||||
Baxter sent Urgent Device Correction letters dated 12/21/05 to the direct accounts on the same date via first class mail. The letters informed the accounts of the potential for unrequested PCA doses due to an electrical short in the PCA circuit simulating repeated pressing of the PCA button. The unrequested bolus doses will not exceed the programmed prescription limits. The letter listed three conditions identified that can produce an electrical short in the PCA circuit and simulate repeated pressing of the PCA button: * Damaged PCA cord or button, * Partial sticking of the PCA button, and * Fluid ingress into the pump or PCA button. Information was provided to reduce the potential for these conditions from occurring during use of the pumps. Customers were asked to ensure that prior to or after each use the PCA cord is intact and has no cuts or missing insulation, and that the pump connector and the button are securely attached to the cord. They were also asked to immediately take the pump and PCA cord out of service for repair if the pump displays 'Release the PCA Button' and the PCA button is not being intentionally pressed, as there may be a mechanical or electronic fault in the PCA button. They were also asked two avoid getting liquids inside the pump as permanent damage may result. Baxter recommended that the institutions implement a regular preventative maintenance program and periodic replacement of the PCA cords based on their own specific usage patterns. Any questions were directed to the Center for One Baxter at 1-800-422-9837. Baxter sent a follow-up recall letter to the accounts on 6/21/06, providing them with an Operator's Manual Addendum for the AP II Infusion Pump and the PCA II Infusion Pump, with the warnings to ensure that prior to or after each use that the PCA cord is intact and has no cuts or missing insulation, and that the pump connector and the button are securely attached to the cord; to avoid getting liquids inside the pump; and | |||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
30,000 pumps | |||||||||||||||||||||||||||
Nationwide including Puerto Rico, and internationally to Canada, Chile, China, Hong Kong, Korea, Kuwait, Malaysia, Taiwan and Saudi Arabia | |||||||||||||||||||||||||||
TPLC Device Report | |||||||||||||||||||||||||||
1 A record in this database is created when a firm initiates a correction or removal action. The record is updated if the FDA identifies a violation and classifies the action as a recall, and it is updated for a final time when the recall is terminated. Learn more about medical device recalls. 2 Per FDA policy, recall cause determinations are subject to modification up to the point of termination of the recall. 3 For details about termination of a recall see Code of Federal Regulations (CFR) Title 21 §7.55. | |||||||||||||||||||||||||||
510(K) Database | 510(K)s with Product Code = MEA and Original Applicant = C.R. BARD, INC. |
0Replies | 3 years agoTEST POST test post to test email notificationsReply |
-Anna1752 4 years ago | 4 years agoMaximum Infusion Rate Can the pump really only go as high as 99.9ml/hr? Or is this only in Continuous rate mode? Reply |
1Reply5 years ago | 5 years agoElectrical fault 13 Anyone know what would cause electrical fault 13? Reply |
DOCUMENTS / MANUALSView All
FEATURES
- Intuitive self-prompting programming for quick setup
- One-hour limit and limited parameter entry help ensure patient safety and guards against programming errors
- Internal safety checks help minimize the risk of tampering and errors
- Locking syringe cover and security codes minimize unauthorized operation
- Standard programming routine helps reduce procedural errors and minimizes training
- Built-in history logs successful injections, attempts, alarms, and other operating details (dosage history available in hard copy when connected to a printer)
- Large, back-lit display easily readable even at night
- Easily programmed infusion modes: PCA only, Basal plus PCA, Continuous Basal
- Program by milliliters or milligrams
- Select the syringe option to best suit your needs – prefilled syringes for convenience or standard syringes for cost savings
- Alternate power sources available – “D” size batteries/AC power kit
SPECIFICATIONS
Flow Accuracy | 3 % average linear displacement |
Flow Rate Range | 0.1 to 150 ml/h |
Infusion Pump Type | Patient-Controlled Analgesic (PCA) |
Height | 13 in |
Length | 2.8 in |
Weight | 4.2 lbs with batteries |
Width | 6.3 in |
NEWSView All
Baxter Enters into Exclusive Distribution Agreement with Sigma..
Baxter Acquires Minority Stake in SIGMA with an Option to Purchase Remaining Portion of Company>
DEERFIELD, Ill., (April 15, 2009)> — Baxter International Inc. announced today an exclusive three-year distribution agreement in the United States and international markets with SIGMA International General Medical Apparatus, LLC for..
DEERFIELD, Ill., (April 15, 2009)> — Baxter International Inc. announced today an exclusive three-year distribution agreement in the United States and international markets with SIGMA International General Medical Apparatus, LLC for..